Commit Graph

10 Commits

Author SHA1 Message Date
Aravind Akella
4949c50372 Support restricted mode in SensorService.
In restricted mode, only CTS tests can register for sensors or call flush() on them. The requests
from other applications will be ignored.

Change-Id: Ieb923df3e0cfe3390fe2d052af776da79589744b
2015-03-24 15:41:35 -07:00
Aravind Akella
724d91d778 Sensor batching. Changes to the native code.
Bug: 10109508
Change-Id: I7333f3aac76125a8226a4c99c901fb904588df04
2013-09-03 17:04:36 -07:00
Mathias Agopian
cdd7d8bc14 resolved conflicts for merge of 00aea5c5 to master
Change-Id: Ie1769be863ee2d411eae451907a928db57882e14
2013-07-12 14:19:10 -07:00
Mathias Agopian
ac9a96da65 fix a dead-lock in sensorservice
sensorservice would deadlock if for some reason
a sensor failed to enable.

simplifed the code a bit, and made it behave a little
closer to mr1.1 -- I couldn't convince myself that
some changes in how locks were used were correct.

Bug: 9794362
Change-Id: I6110f5dbb67e543f1c71d127de2299232badb36a
2013-07-12 02:08:06 -07:00
Mathias Agopian
ba02cd2f6c improve sensorservice's dumpsys
it now displays the reported trigger mode properly, as well as
the number and type of the last received data

Change-Id: I2ff64b32ab71f1332bc2e09671c8c02bb9550490
2013-07-08 15:44:41 -07:00
Jaikumar Ganesh
4c01b1ad80 Fix activation issue with auto disabled sensors.
Auto disabled sensors get auto disabled after trigger.
An activation after this wasn't working because the
state was not being reset.

b/8609561

Change-Id: If72c9f27345e91671d7ad0a7a066f6dc3d255b78
2013-04-17 14:58:22 -07:00
Jaikumar Ganesh
4342fdf14f Sensor changes.
1. Some sensors can wake up the AP. Add wakelocks.
2. Handle backward compatibility for rotation vector
   heading accuracy.
3. Cleanup auto disabled sensors.
4. Fix race condition between enable and dispatch.

Change-Id: I39dddf12e208d83cd288201986ee994312555820
2013-04-12 09:34:44 -07:00
Mathias Agopian
667102f6b0 improve sensorservice dumpsys
Change-Id: I8b53d5cab884c3aca16d95df5fbf288368d52e8b
2012-06-27 17:07:55 -07:00
Mathias Agopian
50b66767f6 fix [3237242] sensormanager sensor active count gets out of sync
whether a physical sensor needed to be active or not was managed by
a simpe reference counter; unfortunatelly nothing prevented it to
get out of sync if a sensor was disabled more than once.

sensorservice already maintainted a list of all the "clients"
connected to a physical sensor; we now use that list to determine if
a sensor should be enabled. This can never be "out-of-sync" since
this is the only data structure linking a sensor to a user of that
sensor.

also removed the isEnabled() method, which was never used and
implemented wrongly (since it didn't take into account that a sensor
could be disabled for a client but not of another).

Change-Id: I789affb877728ca957e99f7ba749def37c4db1c7
2012-06-27 17:07:54 -07:00
Mathias Agopian
f001c92436 Add support for virtual sensors.
Rework sensorservice to allow "virtual sensors", that is
sensors that report a synthetized value based on real sensors.

the main change to sensorservice is around managing which real
sensor need to be activated and which rate to use.

The logic for all this has been moved into SensorDevice, which
essentially wraps the sensor HAL but adds two features to it:
- it keeps track of which sensors need to be activated
- it keeps track of what rate needs to be used

For this purpose an "identity" is associated with each real sensor
activation, so we can track them.

On start-up we check for gravity, linear-acceleration and
rotation-vector sensors, if they're not present in the HAL, we
synthetize them in sensor-service.

Change-Id: I841db2c1b37ef127ed571efa21732ecc5adf1800
2012-06-27 17:07:54 -07:00